SPECIFICATIONS

MODEL Series ADX-2NR/4NR
Standard ANSI/UL 864
Primary AC 120VAC @ 2.1 Amps 60hz or 220VAC @ 1.1Amps 50hz
Output DC 24VDC @ 5.25 Amps (4 Amps available for system power)
Power Supply 5.25 Amps integrated
Charger Current 1.5 Amps max.
Dimensions 14.5″ W x 24″ H x 5″ D
Weight 31 lbs. (without batteries)
Weight 31 lbs. (without batteries)
Color Red (optional gray)
Color Red (optional gray)
Material ABS/steel enclosure
Display 8 line x 40 character LCD (320 characters total)
Network Dual RS485 ports (64 panels max.)
Zones 500 network wide software zones per system
SLC loops 2 or 4 (class A, “style 6 or 7” or class B, “style 4”)
Devices per loop 127 sensors & modules, plus 127 analog sounder bases, 254 total
Addresses per panel (800 addresses + sub-addresses max. per panel)
NAC Outputs 4) 2.5 Amps @ 24VDC (class B)
Relay Outputs (5) Form C 1 Amp @ 30VDC
Voltage Outputs (3) 500mA @ 24VDC
Aux. Power 500mA @ 24VDC
Aux. Inputs (8) digital pull downs
PC Port / Printer RS232
Operating Temp. 32°F (0°C) 120°F (49°C)
Relative Humidity 85% RH Non-Condensing

SPECIFICATIONS

MODEL ADX-NANN
Standard ANSI/UL 864
Input DC 24VDC @ 270mA Max. ( + Aux. Power Load)
Aux. Output DC 24VDC @ 500mA
Dimensions 14.5″ W x 10″ H x 3.3″ D
Weight 9.4 lbs
Color Red
Material ABS/steel enclosure
Operating Temp. 32°F (0°C) 120°F (49°C)
Operating Temp. 32°F (0°C) 120°F (49°C)
Relative Humidity 85% RH Non-Condensing
Relative Humidity 85% RH Non-Condensing
Display 8 line x 40 character LCD (320 characters total)
Network Dual RS485 ports (64 nodes max.)
Relay Outputs (4) Form C 1amp@30VDC
PC Port RS232
Printer Port RS232
Expansion Port RS485 (for optional expansion boards)

SPECIFICATIONS

MODEL Series BFE-C2WBI
Standard Dimension H600mm x W600mm x D300mm
Front Fascia Powder Coated / SS Brush / SS Mirror
Back Box Powder Coated / SS Brush / SS Mirror
Hinge Round Bar / SS Piano Hinges
Lock SS Round Latch Lock

SPECIFICATIONS

MODEL ADX-SANN
Standard ANSI/UL 864
Current Draw Standby: 20mA @ 24VDC; Alarm: 110mA @ 24VDC
Dimensions ADX-SANN: 10.88″ W x 8.00″ H x 1.38″ D
Back Box: 10.38″ W x 7.38″ H x 1.25″ D
Weight 3.5 lbs
Color Red (optional charcoal)
Material ABS/steel enclosure
Operating Temp. 32°F (0°C) 120°F (49°C)
Operating Temp. 32°F (0°C) 120°F (49°C)
Relative Humidity 85% RH Non-Condensing
Relative Humidity 85% RH Non-Condensing
Display 8 line x 40 character LCD (320 characters total)
Network RS485 port

SPECIFICATIONS

MODEL STK-S01
Standard ANSI/UL 268
Operating Voltage 17-41 VDC
Standby Current 450μA
Alarm Current 540μA
Transmission Method DCP – Digital Communication Protocol
Maximum Humidity 95% RH Non-Condensing
UL Temperature Range 32°F to 115°F (0° C to 47° C)
Operating Temperature Range 14°F to 122°F (-10°C to 50°C)
Sensitivity Range 0.7-4.0%/FT@300FPM
0.7-3.86%/FT@2000FPM
0.7-2.65%/FT@4000FPM
Air Velocity Range 0-4000 fpm
Color & Case Material Bone – ABS Blend
Weight 3.4oz (5.1 oz. with 4″ base)
Bases STK-B14, STK-B26, STK-B3SB, STK-B14SCI, STK-B26SCI

SPECIFICATIONS

MODEL STK-H02
Standard ANSI/UL 521
Operating Voltage 17-41 VDC
Standby Current 350μA
Alarm Current 500μA
Transmission Method DCP – Digital Communication Protocol
Rate of Rise 15°F/Min (8.3° C/Min)
UL Temperature Range 135°F to 190°F (57.2° C to 87.8° C)
UL Maximum Spacing 70 feet
Maximum Humidity 95% RH Non-Condensing
Color & Case Material Bone – ABS Blend
Weight 3.2oz (4.9 oz. with 4″ base)
Bases STK-B14, STK-B26, STK-B3SB, STK-B14SCI, STK-B26SCI

SPECIFICATIONS

MODEL STK-M03
Standard ANSI/UL 268
Operating Voltage 17-41 VDC
Standby Current 450μA
Alarm Current 450μA
Transmission Method DCP – Digital Communication Protocol
Maximum Humidity 95% RH Non-Condensing
UL Temperature Range 135°F to 150°F (57° C to 65° C)
Operating Temperature Range 14°F to 122°F (-10°C to 50°C)
Sensitivity Range 0.7-4.0%/FT@300FPM
0.7-3.86%/FT@2000FPM
0.7-2.65%/FT@4000FPM
Air Velocity Range 0-4000 fpm
Color & Case Material Bone – ABS Blend
Weight 4.2oz (5.9 oz. with 4″ base)
Bases STK-B14, STK-B26, STK-B3SB, STK-B14SCI, STK-B26SCI

SPECIFICATIONS

MODEL MID-M10
Standard UL 864
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Average Current Consumption (On S-SC Line) 339μA (Typical); 358μA (Alarm)
Programmable Input 1 Monitoring Inputs
EOL Device 10.0K ohms Resistor
Max. Quantity Per Loop 127
Max. Quantity Per Loop 127
Dimensions 1.75″W x 2.37″H x 0.5″D
Operating Temperature 32°F (0°C) ~ 120°F (49°C)
Mounting 2″ square electrical box
Relative Humidity 90% RH Non-Condensing

SPECIFICATIONS

MODEL MID-CZM
Standard UL 864
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Auxiliary Supply Voltage 18.8 ~ 27.2 VDC
Average Current Consumption (On S-SC Line) 670μA
2-Wire Detector Loop Current Standby Detector Load 1mA Max.
From Auxiliary Supply 60mA Max.
EOL Device 4.7K ohms Resistor
Max. Quantity Per Loop 127
Max. Quantity Per Loop 127
Alarm Threshold Level < 1.5K ohms
Alarm Threshold Level < 1.5K ohms
Wiring Threshold Level > 2.5K ohms & < 6K ohms
Open Circuit Threshold Level > 10K ohms
Max. 2-Wire Conventional Detector (Loop Resistance) 50 ohms (total wire length)
Dimensions 4.2″W x 4.7″H x 1.4″D
Operating Temperature 32°F (0°C) ~ 120°F (49°C)
Mounting 4″ square electrical box
Relative Humidity 90% RH Non-Condensing

SPECIFICATIONS

MODEL MID-R20/I & MID-R21/I
Standard UL 864
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Average Current Consumption 350μA( Typical) 405μA (Alarm)
Contacts R2ML: 2A @ 30VDC / 0.5A @ 120 VAC
R2MH: 8A @ 30VDC / 4.8A @ 250VAC
SCI On Resistance 40m ohm Max. (Normal Condition)
SCI Fault Detection Threshold 12 volts (Typical)
SCI Isolation Current (Short Circuit Condition) 10mA (Typical)
SCI Isolation Current (Short Circuit Condition) 10mA (Typical)
Dimensions 4.2″W x 4.7″H x 1.4″D
Ambient Temperature 32°F (0°C) ~ 120°F (49°C)
Mounting 4″ square electrical box
Relative Humidity 90% RH Non-Condensing

SPECIFICATIONS

MODEL MID-S31
Standard UL 864
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Auxiliary Supply Voltage 24 VDC
Average Current Consumption 154μA (Ty pical) Maximum
Current Consumption on Auxiliary Power Lines Typical 1.15mA
Maximum Output Current 2A @ 2 4 VDC Power Limited
Solenoid Current Consumption Maximum : 443mA
EOL Device 10K ohm s Resistor & 1N5817 Diode
Dimensions 4.2″W x 4.7″H x 1.4″D
Operating Temperature 32°F (0°C) ~ 120°F (49°C)
Mounting 4″ square electrical box
Maximum Output Current 2A@24VDC power limited
Relative Humidity 90% RH Non-Condensing

SPECIFICATIONS

MODEL MID-SCI
Standard UL 864
Supply Voltage (S-SC) 33 ~ 41 VDC
Average CurrentConsumption 270μA (Typical) 10 mA (Active Short Condition)
Visual Indicator (Yellow LED) Normal: Off
Active: On
Dimensions 4.2″W x 4.7″H x 1.4″D
Operating Temperature 32°F (0°C) ~ 120°F (49°C)
Mounting 4″ square electrical box
Relative Humidity 90% RH Non-Condensing